Unipulse f395 Operation Manual page 43

Dynamic force processor
Table of Contents

Advertisement

4.Methods of Connection
・COMPLETE
・WARNING:
・ Hysteresis return:
Accumulated
29
3) When the Multi-Hold / Waveform Comparison / Waveform
and Displacement Comparison mode is used.
Not used. (OK displacement 2 turns ON.)
4) When the output selection is ON, LO displacement 2, OK
displacement 2 and HI displacement 2 are changed to
"Status" and "Level Edge" outputs. (For details, see "Select
output" P.27.)
:This signal is output upon judgment or hold. Read each output
signal after confirming that this signal is ON.
(For output timing, see "10-3. Hold Functions" P48, and "13-6.
Timing in the Waveform Comparison / Waveform and
Displacement Comparison Mode" P76.)
COMPLETE may be output earlier than each judgment output due to
signal delay in wiring, etc. Do not take in judgment at the ON edge of
the COMPLETE signal.
This signal is output when displacement input is used and sampling is thinned out.
(See "13-5. Waveform and Displacement Comparison Mode" P74.)
This signal is turned ON when return waveform sampling starts, and is turned OFF
upon completion in the Hysteresis / Hysteresis 2 mode. This signal is turned OFF in
go waveform sampling and in other modes. (See "11-2. Setting and Operating
Method" P64.)
*1
: When multiple operation channels are switched, once HI2 / LO2 results,
HI2 / LO2 remains ON, and OK2 turns OFF.

Hide quick links: