Graphic Operation Terminal F930GOT
13.2
Connection of bar code reader
13.2.1
Connection
• System configuration
* A bar code reader is connected to the RS-232C connector. Accordingly, the printout function
or the two-port interface function cannot be used together with a bar code reader.
If the F930GOT is connected to the PLC via RS-232C, the bar code reader connection func-
tion is not available.
13.2.2
Communication specifications
The F930GOT can be connected to a bar code reader which satisfies the communication
specifications and the communication format shown below.
• Communication specifications
Communication port
Baud rate
Data length
Stop bit length
Parity
• Communication format
Data
Data
Header
End code : CR (0DH)
RS232C
9600 bps
8 bits
1 bit
Even
CR (0DH)
: ASCII code
: None
Additional Functions (in V.2.00 or later) 13
• Connection
F930GOT: RS-232C connector
1:Unused
5
9
2:RD(RXD)
4
8
3:SD(TXD)
3
7
2
4:DTR
6
1
5:SG
6:DSR
7:RTS
8:CTS
9: