Appendix 1 For customers who have replaced the older model with this
inverter

Appendix 1-1 Replacement of the FR-A500 series

(1) Instructions for installation
1) Removal procedure of the front cover was changed. (with screws) Please note. (Refer to page 5.)
2) Removal procedure of the operation panel was changed. (with screws) Please note. (Refer to page 5.)
3) Plug-in options of the A500 series are not compatible.
4) Operation panel (FR-DU04) can not be used.
5) Setup software (FR-SW0-SETUP/FR-SW1-SETUP) can not be used.
(2) Wiring instructions
1) The control circuit terminal block can be used for the FR-A700 series without removing wiring.
Note that the wiring cover (00023 to 00620) is not compatible.
FR-A500 series
(Note that the relay output 2 (A2, B2, C2) specific for the FR-A700 series can not be used with the FR-A500 series
terminals.)
(3) Instructions for continuous use of the FR-PU04 (parameter unit)
1) For the FR-A700 series, many functions (parameters) have been added. When setting these parameters, the
parameter name and setting range are not displayed. User initial value list and user clear of the HELP function
can not be used.
2) For the FR-A700 series, many protective functions have been added. These functions activate, but all alarms
are displayed as "Fault 14". When the alarm history has been checked, "E.14" appears. Added alarm display
will not appear on the parameter unit.
3) User initial value setting can not be used.
4) User registration/clear (user group 2) can not be used.
5) Parameter copy/verification function can not be used.
(4) Parameter resetting
It is easy if you use setup software (FR-Configurator).
442