2. FUNCTION, CHARACTERISTICS AND CONFIGURATION
● Power supply type selection function (200 VAC input type)
Either a 3-phase, 200 VAC type or the single phase, 200 VAC type main power supply can be selected.
After selecting either one, simply turn the control power supply on again, no other parameter settings
are necessary. (Since some types of motors have different 3- or single-phase properties, refer to the
combination specifications in Section 9.)
● Applicable to wiring-saved incremental & absolute encoders
The same amplifier is applicable to an incremental encoder (INC-E) and an absolute encoder (ABS-E)
simply by changing the appropriate parameters using the remote operator.
Different motors, however, are required for the INC-E and the ABS-E, respectively.
● Applicable to absolute sensor (ABS-R II)
Applicable to an absolute sensor (ABS-R II).
● Applicable to Wiring-saved absolute sensor (ABS-E.S1)
Applicable to a wiring-saved absolute sensor (ABS-E.S1). Absolute sensor can be wiring-saved. In
use to application not requiring holding multi-rotational part, wiring number can be less then that for
wiring-saved incremental encoder (INC-E). In case of not requiring holding multi-rotational part, battery
connection is not necessary (Need parameter setting to select functions).
Applicable Servo Amplifiers to absolute sensor (ABS-R II) and wiring-saved absolute sensor
(ABS-E.S1) have different internal circuits from incremental (INC-E) and absolute (ABS-E)
encoder-type amplifiers. Use product applicable to an absolute sensor.