Sanyo SUPER BL P5 Manual page 102

Table of Contents

Advertisement

7. EXPLANATION OF PARAMETERS
● Setting practice
For example, set the speed loop proportional gain to 100 Hz.
According to the basic operating procedure, select 0 from the Mode Select screen, then implement
the following operations:
1
Select page 2 using by
2
Move the cursor to the position corresponding to
the desired number of input digits using
3
Continuously enter 1 0 0 using the 0
to
9
9 keys.
4
The set value is stored in the nonvolatile
memory using
operator operates with the set value.
After completion of the setting, the screen turns
as shown in the figure.
If a value out of the setting range is to be stored
in memory, the screen to the right appears and
storing is not performed.
In this case, retry setting from step 2.
5
Press
To set the next page, start with step 1.
or
key.
1 0
0
key and the remote
to return to the initial screen.
0
or
key.
0
When, for instance,
you tried to store 3200 Hz.
7-7
* Para.
Set1
2
Kvp  =
# # # #
H z
The cursor flashes.
* P a ra .
S e t1
2
K v p   =
1 0 0 H z
    C o m p le te d     2
K v p   =   1 0 0 H z
W R
Invalid           2
Kvp  =
3200 Hz