Sanyo SUPER BL P5 Manual page 145

Table of Contents

Advertisement

7. EXPLANATION OF PARAMETERS
Abbre-
Mode Page
viation
2
3
Func2 Amplifier function select 2
1 If bit 7 is set at "1", an alarm will not be indicated for a CPU error.
2 Bit 4 cannot be changed unless the control power is turned off.
3 Forward revolution refers to the counterclockwise revolution when viewed from the
load (motor shaft) side.
4 The 15 A and 30 A capacity amplifiers do not have built-in regenerative resistors.
• Bit 4 shall be set according to the permissible effective power of the external
The 50 A capacity amplifiers have built-in regenerative resistor.
• When using a built-in regenerative resistor, set bit 4 at "0".
• When using an external regenerative resistor, set bit 4 according to the
Name and description
• A desired monitor output method or
regenerative resister OL time can be
selected.
Func2
7
6
5
4
regenerative resistor used.
permissible effective power of the resistor.
Standard
value
0010-
0000
3
2
1
0
Monitor 1 output polarity
0
Positive output at forward revolution
1
Negative output at forward
Monitor 2 output polarity
0
Positive output at forward revolution
1
Negative output at forward
Monitor 1 output absolute value
0
Negative/positive output
1
Absolute value output
Monitor 2 output absolute value
0
Negative/positive output
1
Absolute value output
Regenerative resistor OL time select
0
Regenerative resistor allowable
effective power: 20 W or lower
1
Regenerative resistor allowable
effective power: Higher than 20 W
Speed control error (SE) detection
0
Enabled
1
Disabled
Alarm output method
0
CODE
1
BIT
Alarm output logic
0
Turned off at an alarm
1
Turned on at an alarm
7-50
Setting
Unit
Remarks
range
0, 1
(
1)
(
3)
2
4

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Super bl py2Super bl py