7. EXPLANATION OF PARAMETERS
Abbre-
Mode Page
viation
2
1
Func0 Amplifier function select 0
1 This function is available only with a servo system that supports the fully closed
design.
2 Selecting a fully closed encoder does not change the divided output. Thus, when you
need a divided output for the fully closed encoder, set Func5 bit4 to "1".
3 When overtravel bits 3 and 4 are internally turned on, they become ineffective if the
overtravel input logic is b-contact. And, they are always in overtravel status if the
overtravel input logic is a-contact.
4 When changing the setting of bit 7 or 6, you must turn the control power off once prior
Name and description
• This parameter selects whether external
signals are made effective or are forcibly
turned on internally. It also selects the
overtravel input logic, the encoder used
(between motor encoder and fully closed
encoder) and the multiplication factor of the
encoder.
Func0
7
6
5
4
Standard
value
0000-
0000
3
2
1
0
SON mask
0
Externally effective
1
Internally forced ON
CN1-36 pin mask
0
Externally effective
1
Internally forced ON
ILM mask
0
Externally effective
1
Internally forced ON
NROT mask
0
Externally effective
1
Internally forced ON
PROT mask
0
Externally effective
1
Internally forced ON
O. T input logic select
0
b-contact
1
a-contact
Switching of fully closed encoder functions
0
Multiplication by 4
1
Multiplication by 1
Position loop encoder select
0
Motor encoder
1
Fully closed encoder
7-47
Setting
Unit
Remarks
range
0, 1
(
3)
(
4)
1
1
2

Hide quick links: