7. EXPLANATION OF PARAMETERS
Abbre-
Mode Page
viation
2
2
Func1 Amplifier function select 1
Whichever approach you select, the current limit is enabled only after the CN1-31 pins
are turned on.
Name and description
• How to use different current limit approaches
Bits 2 to 0 are parameters relevant to current
limit.
The following describes their setting and the
corresponding current limit method available.
Current for forward and
When
backward revolution can be
external
separately set.
analog input
is used
Current for forward and backward revolution is set at the same level.
• Input external analog to PIL input.
When internal current limit is used
Standard
value
Negative polarity
• Inputs negative voltage to NIL input.
• Input positive voltage to PIL input
Positive polarity
• Input external analog to NIL and PIL
input.
• Sets the internal current limit value
(IILM).
7-49
Setting
Unit
Remarks
range
Func1
* * * * * 0 0 1
* * * * * 1 0 1
* * * * * * 1 1
* * * * * * * 0