Sanyo SUPER BL P5 Manual page 176

Table of Contents

Advertisement

8. MAINTENANCE
Alarm Status
Segment LED
Alarm Code
Display
ALM8,4,2,1
(Comes off)
Alarm code 0,1 indicates: when Func2/ bit7,6 ="0,0", "0"= output open and "1"= output short.
Operating state when alarm occurred
OPERATING STATE
When control power supply is turned on
During operation
Corrective Measures
1
Faulty amplifier control circuit
2
Weak internal 5V power due to short-circuit of
input/output wiring of signal line of amplifier
3
Faulty operation due to noise
4
In maintenance mode.
Abbreviation
1111
CPUE
CAUSE
Alarm
Alarm
Name
Clear
Amplifier
Not
Built-in CPU of amplifier is malfunctioning
error
Possible
POSSIBLE CAUSES
1
Replace servo amplifier
Disconnect all connectors and turn power supply on
→ If 7 segment LED blinks, check and repair
short-circuit on signal line.
• Check if earth cable of amplifier is correctly
grounded.
• Add ferrite core as noise measure.
• Maintenance mode SW on the front of Amplifier
(see Chapter 3 front view of Servo Amplifier) is at
maintenance mode.
→ Shut down the control power and return the SW
to normal mode.
8 - 20