8. MAINTENANCE
Alarm Status
Segment LED
Alarm Code
Display
ALM8,4,2,1
Alarm code 0,1 indicates: when Func2/ bit7,6 ="0,0", "0"= output open and "1"= output short.
Operating state when alarm occurred
OPERATING STATE
When control power supply is turned on
After operating for a short period
Corrective Measures
1
Although the system is of not connecting
external thermal, Amplifier sets to external
overheat detection valid.
2
In case of system connecting external
thermal, wiring is disconnected.
3
External thermal terminal (external
regenerative resistor) operated.
4
Faulty servo amplifier control board
Abbreviation
0011
EXOH
CAUSE
Alarm
Alarm
Name
Clear
External
Possible External overheat was detected.
overheat
POSSIBLE CAUSES
1
CORRECTIVE MEASURES
Change parameter setting to external overheat
detection invalid (Mode2-Page4 Func3-bit4,5)
Check and correct wiring.
• Review operational conditions.
• Increase capacity of external regenerative resistor
Replace servo amplifier