7. EXPLANATION OF PARAMETERS
Abbre-
Mode Page
viation
1
12
SILM
13
THB
14
VCMS Velocity command scale
15
TCMS Torque command scale
Name and description
Sequence current limit value
• Sets a current limit value for holding brake
sequencing, overtravel or JOG operation.
• This setting is available within the range of
IP/IR × 100.
Holding brake excitation timing
• Sets the holding brake excitation timing.
• Select "0" when this function is not used.
• Sets a velocity command scale corresponding
to 1 V of the command voltage.
• Sets a torque command scale corresponding
to 1 V of the command voltage.
Standard
value
120
300
500
50
7-41
Setting
Unit
Remarks
range
%
30 to
(IP/IR)
× 100
mSec
0 to
Timing setting
1000
is available in
multiples of
4 msec.
-1
min
/
0 to
V
3000
%/V
0 to
400