7. EXPLANATION OF PARAMETERS
Abbre-
Mode Page
viation
1
16
MENP Motor encoder pulse number
17
EENP Number of pulses of fully closed encoder
18
OLWL Over load warning level
1 When changing your setting, set Func6 bit7 to "1" from Screen Mode 2 prior to the
change.
2 Turn the control power off once before the change.
Name and description
• Sets the number of pulses of the encoder
used.
• The following shows the number of encoder
pulse in standard combination:
Saved wiring incremental encoder
--- 2000 P/R.
Absolute encoder --- 2048 P/R.
• Sets the number of pulses of the encoder
used in terms of the motor shaft.
• This parameter is usable only on the servo
system that supports the fully closed design.
• This parameter is for warning output before
getting into over load alarm status and motor
stoppage (see 9.6 warning output for over
load warning output function).
• Possible setting level range is from 30 to 99%
when over load alarm level is regarded as
100%. There will be no over load warning
output in setting 100%.
Standard
value
$$$$
$$$$
100
7-42
Setting
Unit
Remarks
range
P/R
500 to
65535
(
1)
(
2)
P/R
500 to
65535
(
1)
(
2)
%
30 to
(
2)
100