9. SPECIFICATIONS
1. The brake response time was measured in the following circuit.
2. The brake release and braking delay time refers to those in the Fig. below.
3. The brake release time is the same for both the varistor and the diode.
100VAC
60Hz
Exciting
voltage
Exciting
current
100%
Holding
torque
Brake release time
E DC
E DC
Ib
Braking delay time
9-64
Ib
Brake
Brake
100%

Hide quick links: