Sony MVS-8000X User Manual page 198

Multi-format production switcher processor with ccp-8000 series center control panel volume 1
Hide thumbs Also See for MVS-8000X:
Table of Contents

Advertisement

3
Setting the independent key transition rate in the numeric
keypad control block
Notes
You cannot use the numeric keypad control block to set the transition rate for
a simple transition.
1
2
3
To enter a difference from the current value
After pressing the [+/–] button, enter the difference and press the [TRIM]
button.
To change the sign (+ or –), press the [+/–] button.
Setting the independent key transition rate in the Multifunction
Flexi Pad control block
For example, to set the independent key transition rate for M/E-1 key1, carry
out the following procedures.
198
Independent Key Transitions
• To cancel the entry, press any of the six buttons in the leftmost column
([WIPE], [DME], ...) or the [TRANS RATE] button.
For details of frame input mode and timecode input mode, see page 176.
Press the [ENTR] button.
In the numeric keypad control block, hold down the [TRANS RATE]
button, and in the independent key transition control block, press the
delegation button [KEY1] to [KEY8] ([DSK1] to [DSK8] in the PGM/PST
bank) for the key for which you want to set the transition rate.
The numeric keypad control block changes to the mode for inputting the
independent key transition rate, and its display now shows the
corresponding region name and the current transition rate set for the
region.
With the numeric keypad, enter the transition rate.
• Enter a value of up to three digits.
• To clear the entry value, press the [CLR] button.
For details of frame input mode and timecode input mode, see page 176.
Press the [ENTER] button.
This confirms the entry, and the selected region name and the set transition
rate appear in the numeric keypad control block display.