Command Byte: 'X'
Parameters: '?' returns the configuration of the communications port that the query was received on. "1?" returns
information on COM1. "2?" returns information on COM2. "R?" returns RS-485 Configuration.
Response for '?', '1?', and '2?': "CBBBBBBPDS"
C Communications port; 1=COM1, 2=COM2.
BBBBBB Current baud rate. Example: 019200.
P Parity, 'N', 'O', or 'E'.
D Data bits, '8' or '7'.
S Stop bits, '1' or '2'.
Response for 'R?': "ABC"
A
A is 4 or 2 Wire
B
B is T (Terminated) or U (Unterminated)
C
C is RS 485 address
Compatibility: Not available when talking to an amplifier via a Digital Outdoor Controller.
Notes: See also the Set Serial Configuration command.
MNC-0500-038