70. Ring Redundant Protocol (RRP) Commands
fail_period
Specify the fail period time to detect communication failure. The factory default is 2 sec.
<2-5 sec>
Specify the time between 2 and 5 seconds.
polling_interval and fail_period are not allowed to set the same value.
ring_guard_port
(Option)Specify the ring guard function state. The factory default is "disable".
primary
Specify to enable the ring guard and set the target port to primary port.
secondary
Specify to enable the ring guard and set the target port to secondary port.
both
Specify to enable the ring guard and set the target port to primary and secondary
port.
disable
Specify to disable the ring guard.
 Restrictions
Only Administrator and Operator-level users can issue this command.
 Example
To change the "pc-ring" domain settings to node type=Transit, control VLAN=30,
primary port=9, secondary port=10, data VLAN=1, polling interval=1, and fail period=2:
Zxxx0:admin# config rrp domain pc-ring type transit control_vlan_id 30 primary_port
9 secondary_port 10 data_vlan_id 1 polling_interval 1 fail_period 2
Command: config rrp domain pc-ring type transit control_vlan_id 30 primary_port 9
secondary_port 10 data_vlan_id 1 polling_interval 1 fail_period 2
Success.
Zxxx0:admin#
70.2. create rrp domain
 Description
This command is used to create the RRP domain.
 Format
create rrp domain <domain name> type {master|transit} control_vlan_id <vlanid>
data_vlan_id <vid list> primary_port <port> secondary_port <port num> [polling_interval <1-
2sec>] [fail_period <2-5sec>] [ring_guard_port {primary|secondary|both|disable}]