Trouble Conditions (See Troubleshooting Guide also)
Information
"Check" and
"Battery"
Displays

Power Failure

Other Displays

(Fixed Word displays
are in parentheses)
www.PDF-Zoo.com
• The "
EXIT ALARM
interior zone occurs within two minutes after the end of an exit delay.
In any of the previous cases, use a second OFF sequence (code plus OFF
key) to clear the display.
General
The word "CHECK" on the keypad's display, accompanied by a rapid
"beeping" at the keypad, indicates that there is a trouble condition in the
system. The audible warning sound can be silenced by pressing any key.
Instruct users to call for service immediately upon seeing any of the following
messages.
• A display of "
problem exists with the displayed zone(s) and requires attention.
• A display of "
and a zone expander or wireless receiver is interrupted. Check the wiring
and DIP switch settings on the units.
• If there are wireless sensors in the system, the CHECK condition may
also be caused by some change in the environment that prevents the
receiver from receiving signals from a particular sensor.
• A display of
keypads) with no zone number indicates that the system's main standby
battery is weak.
• A display of
with a zone number and a once per minute "beeping" at the keypad
indicates that a low battery condition exists in the wireless sensor displayed
(zone "00" indicates a wireless keypad). If the battery is not replaced within
30 days, a CHECK display may occur.
Note: Some wireless sensors contain a non-replaceable long-life battery
which requires replacement of the entire unit at the end of battery life
(e.g., Nos. 5802, 5802CP).
• If there is no keypad display at all, and the POWER indicator (if
present) is not lit, operating power for the system has stopped and the
system is inoperative.
Note:
The control panel will power up in its previous state (armed or
disarmed) after a complete power failure, but will not retain any
memory of bypasses.
• If the message "
keypads) is displayed, and the POWER indicator (if present) is off, the
keypad is operating on battery power only.
Note: There is a random delay up to 48 minutes before the system will
report an AC failure to the central station. The keypad response is about 6
seconds. The restore report has a random delay of up to 12 minutes (if the
AC failure report was sent).
• If the battery standby capacity is used up during a prolonged AC
power outage, the control's auxiliary power will shut down to minimize
deep discharge of the battery.
Busy-Standby (
system is disabled.
Modem Comm (CC) The system is in communication with the central station
for change of function or status verification.
Comm. Failure (FC) A communication failure has occurred.
Open Circuit (OC) The keypad is not receiving signals from the control and
sees an open circuit.
Long Rng Trbl (bF) Back-up LRR communication failure.
firealarmresources.com
" display, etc. will also result if an alarm from an exit or
" and one or more zone numbers indicates that a
CHECK
" and 09 indicates that communication between control
CHECK
(Fixed-word keypads) or
"BAT"
(Fixed-word keypads) or
"BAT"
" (Alpha keypads) or "
AC LOSS
dI
). If this remains displayed for more than 1 minute, the
– 76 –
(Alpha
"SYSTEM LO BAT"
(Alpha keypads)
"LO BAT"
" (Fixed-word