Error Logger Register - Motorola MVME5100 Programmer's Reference Manual

Hide thumbs Also See for MVME5100:
Table of Contents

Advertisement

Error Logger Register

Address
Bit
Name
Operation
Reset
elog
escb
esen
embt
http://www.motorola.com/computer/literature
$FEF80030
ERR_SYNDROME
READ ONLY
0P
When set, elog indicates that a single- or a multiple-bit
error has been logged by the SMC. If elog is set by a
multiple-bit error, then no more errors will be logged until
software clears it. If elog is set by a single-bit error, then
no more single-bit errors will be logged until software
clears it, however if elog is set by a single-bit error and a
multiple-bit error occurs, the multiple-bit error will be
logged and the single-bit error information overwritten.
elog can only be set by the logging of an error and cleared
by the writing of a one to itself or by power-up reset.
escb indicates the entity that was accessing SDRAM at
the last logging of a single- or multiple-bit error by the
SMC. If escb is 1, it indicates that the scrubber was
accessing SDRAM. If escb is 0, it indicates that the
PPC60x bus master was accessing SDRAM.
When set, esen allows errors that occur during scrubs to
be logged. When cleared, esen does not allow errors that
occur during scrubs to be logged.
embt is set by the logging of a multiple-bit error. It is
cleared by the logging of a single-bit error. It is undefined
after power-up reset. The syndrome code is meaningless if
its embt bit is set.
Programming Model
SBE_COUNT
READ/WRITE
0P
3-49