Duress Code A duress code can only set or unset the system. When user
employs a duress code the control unit notifies the alarm receiving centre.
The Installer must program your system to provide this feature, and you
must agree with your alarm installer and the ARC what action the ARC
should take on receiving a duress message. A duress code cannot have a
remote or prox tag, or any access to the user menu.
Guard A guard can only unset the system when it is in alarm, reset it, and
then set the system again. A guard cannot change their own access code
or add/remove another user. In a ward based system the guard can be
allocated to one or more wards, which are the only parts of the system that
they can set and unset.
Set Only This type of user can set the system, but not unset it. A set only
user cannot change their access code or add/delete another user. In a
ward based system a Set Only user can be allocated to one or more wards,
which are the only parts of the system that the user can set.
Easy Set This type of user is intended for setting and unsetting one or
more wards, without having to choose which ward to set. If one or more
wards allocated to the user are already set then the control unit will unset
those wards when the user presents their tag or enters their access code.
When the user presents their tag (or enters the access code) again then
the control unit sets all the wards allocated to the user – even if there are
any alerts present. (If any zones are open in those wards then the control
unit will not set the system.)
Shunt Group This type of user code is used purely for activating and
deactivating shunt groups (see page 38). The installer must allocate zones
to shunt groups, and then a Master User or Admin User can create one or
more shunt group access codes allocated to any of those shunt groups.
For details on how to add and remove users see page 40.

Identifying Users

The control unit identifies each user internally by a unique number. The
number is in the range 01 to 50 for the Menvier30, 001 to 100 for the
Menvier40, 001 to 250 for Menvier100, and 001 to 500 for the Menvier300.
When a Master User or Administrator adds or edits other users the keypad
shows user numbers as "User nnn", for example "User 001" or "User 023".
To help Master Users and Administrators identify other users the control
unit allows each user to have a 12 character name. The Master User or
Administrator keys in the name when adding the user to the system. If a
user has a name on the system, then the control unit shows that name on
Page 9