Access To The System; Access Codes - Eaton Menvier 20 Administrator's And User Manual

Table of Contents

Advertisement

1. Introduction
Menvier30/40/100/300
the keypad when the Administrator is looking at the log. If the user does not
have a name, then the keypad shows the user number instead.
There are also some "special" users with numbers above the normal range
– see page 58.
Note that the User number is not the same as the access code, see below.

Access to the System

To operate the system a user must identify themselves, either by entering a
valid access code on the keypad or by presenting a proximity tag to the
front of the keypad (see page 11).
Access code and proximity tag act as unique identifiers for each user, and
may be used interchangeably at any time.

Access Codes

In a Security Grade 2 system access codes are four digits long, providing a
total of 10,000 different codes, running from "0000" to "9999". In a Security
Grade 3 system access codes are six digits long, providing a total of
1,000,000 different codes, from "000000" to "999999".
When delivered from the factory the control unit recognises just one user,
and this user has Master User privileges (see page 8).
In Security Grade 2 the Master User's default access code is "5678"; in
Security Grade 3 it is "567800". By default the master User does not have
any tag or other device registered to their account.
Eaton's Security Business recommend that you change the default
access code as soon as possible (see page 41).
Codes 0000 (or 000000) to 9999 (or 999999) are available but Eaton's
Security Business recommends that you avoid easily memorised codes
such a 0000, 999999 or 654321.
The installer has their own access code which they cannot use to set or
unset the alarm system. Neither can they use that code to change details of
other users registered to the system. Similarly, the Master User code has
no access to any installer programming menus and cannot be used to edit
the Installer code.
Page 10

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Menvier 100Menvier 300Menvier 40

Table of Contents