Lucent Technologies MERLIN LEGEND Release 6.0 System Programming Manual page 803

Communications system
Hide thumbs Also See for MERLIN LEGEND Release 6.0:
Table of Contents

Advertisement

MERLIN LEGEND Communications System Release 6.0
System Programming 555-660-111
4
Common Administrative Procedures
System Features
Recall Timer
Use this procedure to designate the length of the timed flash that is sent when
Recall is used to disconnect a call and get a new dial tone without hanging up.
Both the interval of the timed flash and how Recall works depend on the type of
telephone and system operating mode.
The recall timer should be reset if multiline telephone users experience either of
the following problems:
Nothing happens when the user presses the Recall button on an outside
call. This indicates that the interval is too short and should be increased to
650 milliseconds or 1 second.
In a system operating in Behind Switch mode, the call is disconnected
when the user presses the Recall button on an outside call. This indicates
that the interval is too long and should be decreased to 350 milliseconds.
Summary: Recall Timer
Programmable by
Mode
Idle Condition
Planning Form
Factory Setting
Valid Entries
Inspect
Copy Option
Console Procedure
PC Procedure
Interdigit Timers
This procedure to program interdigit timers has not yet been implemented. If
situations occur where a caller is attempting to make an outside call and becomes
connected to an incoming call, the caller may not be able to put the incoming call
on hold or transfer the call. Setting interdigit timers to shorter times permits the
call to be put on hold or transferred. If you are experiencing these types of
problems, call the Lucent Technologies BCS Helpline at 1 800 628-2888.
System Manager
All
Not required
Form 8a, System Features
450 ms
350 ms, 450 ms, 650 ms, 1 second
No
No
More
É  Å
Select time
4
4
Select time
 Ç
4
Issue 1
February 1998
Page 4-333