Table 4–2.

Timers and Counters

Timer/Counter
Purpose
T200 Timer
Maximum response time
T203 Timer
Maximum time
N200 Counter
Maximum transmissions
N201 Counter
Maximum octets
K Counter
Maximum outstanding
I-frames
T303 Timer
Set up timeout
T305 Timer
Disconnect timeout
T308 Timer
Release timeout
T309 Timer
Signal loss
T310 Timer
Call Proc. timeout
T313 Timer
Connect timeout
T316 Timer
Restart timeout
System Manager
All
Not required
Form 3b, Incoming Trunks: DS1 Connectivity (100D module)
See
Table 4–2
See
Table 4–2
No
No
/LQHV7UXQNV
35,
(QWHU
Select timer/counter
Æ È È Ã
(QWHU
and so on
U
I
 Ç Ç Ç Ç
counter
+
Factory Setting
1 second
30 seconds
3 transmissions
260 octets
7 frames
4 seconds
4 seconds
4 seconds
90 seconds
60 seconds
4 seconds
120 seconds
4
3URWRFRO
7LPHUV
Drop
Dial no. of ms/octets/

([LW
([LW
([LW
Type slot no.
Type no. of ms/octets/and so on
Valid Range
1,000 to 3,000 ms
1 to 60 seconds
1 to 5 transmissions
16 to 260 octets
1 to 15 frames
4 to 12 seconds
4 to 30 seconds
4 to 12 seconds
30 to 120 seconds
2 to 120 seconds
4 to 60 seconds
30 to 120 seconds