MERLIN LEGEND Communications System Release 6.0
System Programming 555-660-111
4
Programming Procedures
BRI Facilities
T303 Timer. Times the delay in network response when the
communications system sends a setup message to initiate an outgoing
call.
T305 Timer. Times the delay in network response when the
communications system sends a disconnect message to clear a call.
T308 Timer. Times the delay in network response when the
communications system sends a release message to clear a call.
NOTE:
NOTE:
NOTE:
If you enter an invalid timer value, you hear an error beep and the value that
was previously stored is displayed on the screen.
Table 4–4
threshold.
Table 4–4.

Timers

Timer/
Counter
Purpose
T200 Timer
maximum response time
T203 Timer
maximum time
T303 Timer
Set up timeout
T305 Timer
Disconnect timeout
T308 Timer
Release timeout
Summary: Timers
Programmable by
Mode
Idle Condition
Planning Form
Factory Setting
Valid Entries
Inspect
Copy Option
shows the factory setting for each timer and the valid range for each
System Manager
Key, Hybrid/PBX
Not required
Form 3i, Incoming Trunks: BRI Options (800 NI-BRI module)
See
Table 4–4
See
Table 4–4
No
No
Factory
Setting
Valid Range
1,000 ms
500 to 5,000 ms 500 ms
33 seconds
10 to 255 sec
4 seconds
2 to 10 sec
30 seconds
2 to 60 sec
4 seconds
2 to 10 sec
4
Issue 1
February 1998
Page 4-247
Increments
1 sec
1 sec
1 sec
1 sec