LUBRICATION SYSTEM
OIL PUMP
REMOVAL
Remove the right crankcase cover (page 9-3).
Remove the oil filter rotor (page 9-5).
Rotate the crankshaft clockwise until the pump mounting
screws are accessible lhrough the oil pump gear cover.
Remove the two screws and the oil pump.
Remove the screws and oil pump cover.
INSPECTION
NOTE:
Measure at several places and use the l a rgest reading to
compare to the service l i mit
If any portion of the oil pump is worn beyond the specified
service l i mits, replace the oil pump as an assembly.
Measure the outer rotor-to-body clearance.
SERVICE LIMIT: 0.40 mm (0.016 in)
Measure the rotor
tip
clearance.
SERVICE LIMIT: 0.20 mm (0.008 in)