Honda Shadow TA200 2001 Manual page 254

Table of Contents

Advertisement

BATTERY/CHARGING
SYSTEM
CURRENT
LEAKAGE
INSPECTION
GROUND
CABLE
Turn the aqui.t
ion
switch off end disconnect the battery nega-
tive cable fran the battery.
Connect the amneter
(+)
probe to the qround cable aud the
arrrneter (-) probe to the
battery (-)
t.errmual .
With the ignition switch off,
check
for current leakage.
NOTE:
lrlhell measuriug cur-rent. us i.nq a
t
e-st er , set it to a high
range, and then bring the range do\ . > . . 1 11 to an appropriate
level. OJrrent flo1,,.
1
higher than the range selected may blow
out the fuse in the tester.
Vlhile
measuring
current, do not turn the
ignition
on. ?
suddei
1
surge of rurrei
1t
may blow out the fuse
i11
the tester.
SPECIFIED CURRENT LEAKAGE: 0.1 mAmax.
If
current
leakage exceeds the specified· -aluc, a shorted
cir-
o..ri.t
1S
likely.
Locate the short by di scormect Lnq connections one by one
aud rneasurduq the cur rent; .
Di.scoimect. the a It.eruat.or 4P connect.or .
Remove the left t'rout side cover (page 2-3).
It is not necessary to rerrove the stator coil to Tn3ke this test,
INSPECTION
NOTE:
ALTERNATOR
ALTERNATOR
4P
CONNECTOR
Check the resistance between following terminals.
STANDARD:
Olarging coil (Yellow -
Yellow) :
0.1- 1.0
(at
20°C/68°F)
Replace the a.It.ernat.ox stator it. readings are tar beyond the
standard.
Refer to section
1/J
for stator .raroval.
CONNECTOR
15-7