Adding A 016 Module At The End Of An Existing System; I Replacing A 008 Opt Module With A 016 Mlx Module - Avaya MERLIN MAGIX Maintenance And Troubleshooting Manual

Integrated system release 2.0 and earlier
Hide thumbs Also See for MERLIN MAGIX:
Table of Contents

Advertisement

Replacing a 008 OPT module with a 016 MLX module.
I
Replacing a 016 T/R module with a 016 MLX module.
I
The procedure for each of the supported configurations is explained in the following sections. If
you have a situation that is different from one of these configurations, you must completely
reprogram the system. A Board Renumber will not correct the logical ID shift.
You may encounter more than one of these configurations while completing an
I
installation. Be sure to finish one procedure completely before you start the procedure
for another configuration. An example of this is when a customer wants to replace one
008 MLX module and one 008 OPT module with two 016 MLX modules. Complete all
steps for the 008 MLX procedure before doing the 008 OPT procedure.
If you are replacing a 016 ETR module with a 016 MLX module, contact the Avaya
I
Customer Care Center at 1 800 628-2888.
CAUTION:
This procedure does not apply for exchanges of any module that includes line/trunk ports. If
you must exchange a line/trunk module (408 GS/LS-ID-MLX, etc.), you must completely
reprogram the entire system manually to restore the customer's configuration. A Board
Renumber procedure should not be used.
Adding a 016 Module at the End of an Existing
System
Follow these steps when you are adding a 016 MLX module to the end of an existing system:
1. Back up the system programming to the customer backup card. Use a filename that describes
the pre-016 MLX configuration-for example, "pre-016 MLX."
2. Print a System Setup report. Determine whether the last slot/slots are programmed with
phantom modules. If there are phantom modules, the programming for these modules will be
removed when the new 016 MLX module is implemented.
3. If no phantom modules are programmed, go to Step 4. If there are phantom modules, print all
Extension Information reports for the extensions and MFMs connected to the phantom
modules. The extensions must be re-programmed after the new 016 MLX module is
implemented.
4. Power down the system and install the 016 MLX module in the next available slot.
5. Power up the system.
6. Perform a Board Renumber procedure ( Sys Program (1)
Board Renum (1)
7. Print an Extension Directory report to verify the new extension numbers on the 016 MLX
module, and program as necessary to meet customer needs.
8. If phantom modules were programmed, re-program the phantom modules, as needed using
the information in the Extension Information reports printed in Step 3.
Yes (2).