I Interpreting Test Results - Avaya MERLIN MAGIX Maintenance And Troubleshooting Manual

Integrated system release 2.0 and earlier
Hide thumbs Also See for MERLIN MAGIX:
Table of Contents

Advertisement

Maintenance and Troubleshooting
Interpreting Test Results
If the test completes successfully, the communication paths on the MLX or 800 NI-BRI modules
are functioning properly. Continue with the next module test or restore the module if you are
finished testing.
If the test fails, find the error message in Table
indicated in the "Corrective Action" column.
Table 6-3. B-Channel Loopback Errors
Error Messages
Slot is not busied-out
Slot empty or not valid
FMWR not in Standby Mode
Test running too long
Not in TEST/STANDBY mode
Any other error
B-Channel Loopback Test
6-12
6-3 ''B-Channel Loopback Errors''
Corrective Action
Exit the test, busy-out the slot, and try again.
Exit the test and try again; be sure to type the correct slot
number. Do not indicate an empty slot or the processor
(00).
Exit the test and try again; if this error persists, record the
errors on the repair tag and replace the module being
tested.
Exit the test and try again; if this error persists, record the
errors on the repair tag and replace the module being
tested.
Exit the test and try again; if this error persists, record the
errors on the repair tag and replace the module being
tested.
Record the errors on the repair tag and replace the
module.