Maintenance and Troubleshooting
Computer Telephony Integration (CTI) Link
Problems
If you experience CTI link problems, you can perform the following maintenance procedures:
''Viewing Status''
I
''CTI Link Test''
I
''Restart''
on page 4-29.
I
''Varying Hiding Time''
I
Review the procedures in Module Problems [programmers: make link to this section
which appears earlier in this chapter] to confirm that the module into which you have
plugged is not faulty.
Before you start maintenance or troubleshooting procedures for the CTI link, verify the following:
The MERLIN MAGIX system is operating in Hybrid/PBX mode.
I
The CTI link is plugged into a port on an 008 MLX, 016 MLX or a 408 MLX module.
I
The link is plugged into the RJ45 jack on the ISDN card in the Telephony Server and the wire
I
connection to the server is complete.
The firmware for the MLX module is of vintage earlier or later than 29. Link administration is
I
prevented on modules using firmware 29.
Viewing Status
This procedure checks extension status and identifies whether the MERLIN MAGIX system
recognizes that the link is physically connected and operational.
Procedure
→
Menu
Maintenance
After selecting Status , the following screen appears.
CTI Link xxxx:
SlotPort: xxxx
Physical Link:
PBX Driver Conn:
Alarms:
Maintenance Busy:
Back
Computer Telephony Integration (CTI) Link Problems
4-28
on page
4-28
on page 4-29.
on page 4-30.
→
→
Port
Station
4
4
4
→
→
Dial port number
→
→
Enter
Status
Back