Busy-Out and Reset

Before running any module test, be sure to busy-out or reset the module.
Busy-out discontinues service from the module being tested to each line and extension only as
I
they become idle. Busy-out is the preferred method, because it does not disrupt calls in
progress.
Reset discontinues service to all lines and extensions on the module instantly.
I
– In-progress calls are dropped if all of the calling parties on the call originate and terminate
on the module being reset.
– If a call is using a line or extension on the module being Reset and another line and/or
extension is involved in the call, the call on the module being reset is put on hold. In this
case, the module can be removed and replaced. However, a demand test cannot be
performed, because the module is not busied-out.
Check the status of the reset module before performing a demand test; use this procedure:
I
Menu
Maintenance
The status screen cannot be used to check the router portion of the 100R INA and
100 DCD modules. You must use 100R INA and 100 DCD management interfaces to
determine the status of the router. For information on the Router Management
interface, refer to the documentation packaged with the 100R INA and 100 DCD
modules.
Once you finish testing a module, you must restore it. Restoring a module terminates the
I
Busy-out or Reset condition.
Slot
Status
6

Busy-Out and Reset

Tests