System Programming Basics

System Programming

The Sys Program option provides the System Programming Menu from which you can perform all
system programming available on the system programming console.
Procedure
To display the System Programming Menu from the SPM Main Menu, follow these steps:
Sys Program
page of the System Programming Menu)
See
''Description of Options in System Programming Menu''
each option on the System Programming Menu.
Board Renumbering with the
016 MLX Module
CAUTION:
For installed MERLIN MAGIX systems:
Replacing one module (such as the 008 MLX module) with the 016 MLX module may
I
result in the shifting of logical IDs and require numerous extension programming changes.
This document includes the supported configurations where you can use the Board
I
Renumber procedure instead of reprogramming the system and includes detailed
procedures that you must follow for each configuration.
For instructions on how to remove or install modules in a carrier, please see "Replacing a
I
Module" in the Installation Guide (document number 555-661-140) for details. If you do not
have the Installation Guide, you can order one by calling the BCS Publications Center at 1
800 457-1235.
Your service call may involve installing a 016 MLX module to replace other telephone modules in
the MERLIN MAGIX Integrated System. Replacing another module with a 016 MLX module may
cause the logical IDs to shift. In some cases, you can use the Board Renumber procedure to
reassign the logical ID numbers to the extension and line ports. In other cases, you must
completely reprogram the entire system to restore the customer's configuration.
The following are SUPPORTED configurations where you can use Board Renumber procedure to
reassign the logical ID numbers:
Adding a 016 MLX module at the end of an existing system.
I
Replacing two 008 MLX modules that are the last two modules in the system with one 016
I
MLX module.
Replacing a 008 MLX module with a 016 MLX module.
I

Board Renumbering with the 016 MLX Module

3-46
Start (System Programming Menu appears)
3
3
Back (to return to previous menu)
on page
3
More (to view the second
2-12
for a brief description of

Advertisement

Table of Contents
loading

Table of Contents