Replacing A 016 T/R Module With A 016 Mlx Module - Avaya MERLIN MAGIX Maintenance And Troubleshooting Manual

Integrated system release 2.0 and earlier
Hide thumbs Also See for MERLIN MAGIX:
Table of Contents

Advertisement

Replacing a 016 T/R Module with a 016 MLX Module

WARNING:
If you are replacing more than one 016 T/R module, repeat Steps 1-15 for each module. Do
not try to replace more than one 016 T/R module at a time, because the system translations
will be and you will need to completely reprogram the entire system manually to restore the
customer's configuration.
This procedure removes any T/R or single-line telephone functionality, any features that
may have been programmed, any buttons (for example Inside Auto Dial) that point to
those extensions.
Follow these steps to replace a 016 T/R module with a 016 MLX module:
1. Back up the system programming to the customer backup card. Use a filename that describes
the pre-016 MLX configuration-for example, "pre-016 MLX."
2. Print a System Setup report. Determine whether the last slot/slots are programmed with
phantom modules. If there are phantom modules, the programming for these modules will be
removed when the new 016 MLX module is implemented.
3. If no phantom modules are programmed, go to Step 4. If there are phantom modules, print all
Extension Information reports for the extensions and MFMs connected to the phantom
modules. The extensions must be re-programmed after the new 016 MLX module is
implemented.
4. Print an Extension Directory report. (This report also includes phantom extension numbers.)
5. Print a Group Calling Information report.
6. Print a Group Coverage Information report.
7. Print Extension Information reports for all ports on the 016 T/R module that is being replaced.
8. Identify all Inside Auto Dial, Manual Signal, or Extension Pickup buttons programmed on other
telephones that point to the extensions on the 016 T/R module to be replaced. The
programming for these buttons will be removed after the Board Renumber procedure. These
buttons are not shown on the Extension Information report, so you must identify these buttons
with the customer.
9. Power down the system and replace the 016 T/R module with the 016 MLX module.
10. Power up the system.
11. Perform a Board Renumber procedure: Sys Program (1)
Board Renum (4)
12. Print a new Extension Directory report.
13. Print a Group Calling Information report, and compare it to the Group Calling Information
report you printed in Step 5. Since Calling Group extensions may reverse themselves after a
Board Renumber, verify that the extension numbers are in the correct order. If the extensions
are reversed, re-program as necessary to put in correct order.
Yes (2).
3
System (1)
Board Renumbering with the 016 MLX Module