Avaya MERLIN MAGIX Maintenance And Troubleshooting Manual page 56

Integrated system release 2.0 and earlier
Hide thumbs Also See for MERLIN MAGIX:
Table of Contents

Advertisement

Table 2-2. Error Codes–Continued
Error
Codes
Description
7802
SANITY INT NOT GENERATED:
Only applies to modules that have
extension jacks.
or
MERLIN Messaging System software
was upgraded.
7803
NO PORT BOARDS AVAILABLE:
This error is reported when modules
are not present.
7804
INVALID SANITY RESPONSE:
Sanity test receives invalid responses.
Applies only to modules that have
extension jacks.
or
MERLIN Messaging System software
was upgraded.
7805
INVALID SLOT NUMBER:
Rarely occurs.
Software could not process an event
detection because the slot number was
invalid.
7806
NOT IN STANDBY MODE:
Reported during cold start or
background check.
7807
SELF TEST NOT COMPLETED:
Reported during cold start.
7808
TEST RESULT REGISTER BAD:
A module error or processor error
resulted while running test.
7809
TEST STATUS REGISTER BAD:
A module error or processor error
resulted while running test.
780A
DPR TEST NOT COMPLETED:
Reported during cold start.
Error Logs, Access Logs, and System Inventory
Action
Reset the board. If problem persists,
troubleshoot the module.
If MERLIN Messaging System module was
upgraded, no action is required.
No action required. Delete this entry from the
transient log.
Reset the board. If problem persists,
troubleshoot the module.
If MERLIN Messaging System module was
upgraded, no action is required.
No action required; however, if problem
persists, restart the system.
Reset the board. If problem persists,
troubleshoot the module.
Reset the board. If problem persists,
troubleshoot the module.
Reset the board. If problem persists,
troubleshoot the module.
Reset the board. If problem persists,
troubleshoot the module.
If problem persists, troubleshoot the module.
Error Logs
2-15