Incoming Voice Call Test

Place a voice call from a known working telephone to the BRI line under test.
The 800 NI-BRI module must be restored (removed from the Maintenance-Busy state)
before performing this test. See
1. Assign the BRI line to a button on a 4400-Series or MLX display phone.
If using a facility on the system as a destination, also assign the destination facility to a button
on another 4400-Series or MLX display phone.
2. Dial the DN of the BRI line under test at the originating telephone.
3. Verify that alerting is indicated on the button associated with the BRI line being tested.
4. Verify that the originating number appears on the display of the 4400-Series or MLX telephone
programmed with the BRI line under test. Verify that the associated green LED flashes.
5. If the correct number is not displayed, verify that the number dialed and the DFT administration
are correct. If they are incorrect, repeat the test.
6. Answer the call (press line button if necessary) and verify the connection.
7. Verify that the green LED next to this button is on and steady.
8. Disconnect the call at either the originating end or the receiving end.
9. Verify that the green LED next to the button associated with the BRI line under test turns off.

Outgoing Data Call Test

Place a data call from the BRI line under test to either a working facility on the system or a data
endpoint on the premise that is connected to the central office (CO). See the Data and Video
Reference for details regarding setting up a data call with specific equipment.
The 800 NI-BRI module must be restored (removed from the Maintenance-Busy state)
before performing this test. See Restoring the Module.
1. Assign the BRI line to a data terminal.
If using a facility on the system as a destination, assign the destination facility to another data
terminal.
2. Dial the destination number. (In a Centrex environment, it is necessary to dial a 9 before the
destination number.)
Verify the following results and note any failures:
You may hear dial tone at the beginning of dialing and ringback after completion. Alerting
I
may be indicated at the destination.
6
''Restoring the Module''
6
on page 6-31.
NI-1 BRI Provisioning Test