Error Messages
Step count must be 1 through 999
Cause: You tried to use a step count greater than 999.
Action: Use a step count less than 1000.
Step display failed (688)
Cause: System failure or target condition.
Action: Check memory mapping and configuration questions.
Stepping aborted; number steps completed: %d (686)
Cause: This message is displayed if a break was received during a step
command with a step count greater than zero. The break could have been
due to any of the break conditions or a <CTRL>c break. The number of steps
completed is displayed.
Stepping aborted; number steps completed: <STEPS TAKEN>
Cause: Stepping aborted because <CTRL>c or software breakpoint was hit,
guarded memory was accessed, or some other kind of error occurred.
Action: See the error log display for any abnormal errors. Correct those
errors and then step again.
Stepping complete
Cause: Stepping was completed successfully.
Stepping failed (680)
Cause: Stepping has failed for some reason.
Action: Usually, this error message will occur with other error messages.
Refer to the descriptions of the accompanying error messages to find out
more about why stepping failed.
Symbols not accessible, symbol database not loaded
Cause: You specified a trace list with values expressed using symbols defined
in the source code modules, such as source on, and the database file has not
been loaded into emulation. Example: display trace symbols on.