Emulator/Analyzer Interface Commands
trace
selectively saved by using trace only to enter the specific events to be saved.
When this is used, only the indicated states are stored in the trace memory.
See the QUALIFIER syntax.
repetitively
This initiates a new trace after the results of the previous trace are displayed.
The trace will continue until a stop_trace or a new trace command is issued.
When using this option, you cannot use the on_halt option.
SEQUENCING
Allows you to specify up to seven sequence terms including the trigger. The
analyzer must find each of these terms in the given order before searching for
the trigger. You are limited to four sequence terms if windowing is enabled.
See the SEQUENCING syntax pages for more details.
TRIGGER
This represents the event on the emulation bus to be used as the starting,
ending, or centering event for the trace. See the TRIGGER syntax diagram.
When using this option, you cannot include the on_halt option.
WINDOW
Selectively enables and disables analyzer operation based upon independent
enable and disable terms. This can be used as a simple storage qualifier. Or,
you may use it to further qualify complex trigger specifications. See the
WINDOW syntax pages for details.
Examples
trace after 1000H
trace only address range 1000H thru 1004H
trace after address 1000H occurs 2 only address
range 1000H thru 1004H break_on_trigger
See Also
The copy trace, display trace, load trace, load trace_spec, specify
trace, store trace, and store trace_spec commands.