Emulator/Analyzer Interface Commands
specify
from
--EXPR--
This is used with the specify run from command. An expression is a
combination of numeric values, symbols, operators, and parentheses,
specifying a memory address. See the EXPR syntax diagram.
FCODE
The function code used to define the address space being referenced. See the
syntax diagram for FCODE to see a list of the function codes available and for
an explanation of those codes.
transfer_address
This is used with the specify run from command, and represents the address
from which the program will begin running.
run
This option specifies that the emulator will run from either an expression or
from the transfer address when a CMB EXECUTE signal is received.
TRACE
This option specifies that a trace measurement will be taken when a CMB
EXECUTE signal is received.
until
Specifies an address where program execution is to stop. The emulator will
set a software breakpoint at this address and stop execution of your program
when it reaches this address and enter the monitor.
Examples
specify run from START
specify trace after address 1234H
See Also
The cmb_execute command.