Error Messages
Period not in 1/2/5 sequence: <period> (2021)
Cause: This error message occurs when the external timing sample period is
not in a 1/2/5 sequence; for example, 10ns, 20ns, 50ns, 100ns, 200ns, 500ns,
1us, 2us, 5us, etc. Some examples of invalid sample period specifications are:
12ns, 18ns, 25ns, 60ns, 80ns, etc.
Action: Use a number in the 1/2/5 sequence when specifying the external
timing sample period.
Pin is %s at reset config, emsim definition is %s (177)
Cause: This error message is a result of the display configuration_info
diagnostics command which checks for inconsistencies between the reset
mode configuration value (as specified in the emulator configuration) and
how the EMSIM registers are programmed.
Program counter is odd (84)
Cause: You attempted to modify the program counter to an odd value using
the modify registers command on a processor which expects even alignment
of opcodes.
Action: Modify the program counter only to even numbered values.
The following error messages are unique to the 6833x emulator.
Question file missing or invalid
Cause: Some of the Softkey User Interface files are missing or are corrupted.
Action: Reinstall the host software and try starting the emulation session
again.
Range crosses segment boundary
Cause: On a segment offset processor, an address range is specified that
would cross different segments.
Action: Break the memory command into multiple commands so that the
address ranges start and end in the same segment.
Read memory failed at <PHYSICAL ADDRESS> - store aborted
Cause: While storing memory from the emulator to a file, a read memory
error occurred.
Action: Use the display error_log command to view any errors. You may need
to modify the configuration and map memory before storing the file again.