Error Messages
No valid trace data
Cause: You tried to store trace data before a trace was completed.
Action: Wait until valid trace data is available before attempting to store a
trace.
No tag memory at address: (159)
Cause: You have tried to access tag memory by issuing a modify tags
command, but tag memory has not been defined at the address you specified.
Tag memory is available for address ranges mapped as emulation memory.
Tag memory can also be assigned to target memory ranges by using the "tag"
attribute when mapping.
Normal emulation mode not allowed with HP 64782A (155)
Cause: The HP 64782A emulator, which supports only ACT mode, does not
allow you to configure the emulator for the Normal mode.
Not a valid trace file - load aborted
Cause: You tried to load a file.TR that was not created by the emulation
session.
Action: Only load trace data files that were created by the emulator.
Not an absolute file
No absolute file: <file>
No absolute file, No database: <file>
Cause: You tried to load a file into the emulator that is not an executable or
absolute file, so the host system stopped the load process.
Action: Try your command again, and make sure you specify a valid absolute
file name to be loaded.
Not compatible trace file - load aborted
Cause: You tried to load a file.TR that was created by another type of
emulator.
Action: Only load trace data files that were created by the same type of
emulator.