Error Messages
Invalid option or operand: %s (148)
Cause: You have specified incorrect option(s) to a command. %s, if printed,
indicates the incorrect option(s).
Action: Re-enter the command with the correct syntax. Refer to the on-line
help information.
Invalid trigger duration: <duration> (2031)
Cause: This error occurs when you attempt to specify an external timing
trigger duration which is in the valid range but is not a multiple of 10 ns.
Action: Re-enter the command with the trigger duration as a multiple of 10
ns.
Invalid word access for odd address (2)
Cause: When the access mode is "word", you have attempted to modify a
target system memory location at an odd address.
Action: Either change to an even address or modify the access mode to bytes
if possible.
Invalid word access for odd number of bytes (3)
Cause: When the access mode is "word" and the display mode is "byte", you
have attempted to modify a range of target system memory (perhaps, as
small as a two byte range) with an odd number of byte values.
Action: Either specify an even number of bytes or modify the access mode to
bytes if possible.
Inverse assembly file <INVERSE ASSEMBLER FILENAME> could not
be loaded
Inverse assembly file <INVERSE ASSEMBLER FILENAME> not found,
<filename>
Inverse assembly not available
Cause: The file does not exist.
Action: Reload your interface and/or real-time operating system software.
Inverse assembly not available
Cause: The inverse assembler for your emulator is missing.
Action: Verify proper software installation.