HP 64782 User Manual page 462

For the graphical user interface
Hide thumbs Also See for 64782:
Table of Contents

Advertisement

Error Messages
File perf.out not generated by measurement software
Cause: The file named perf.out exists in the current directory, but it was not
created by the "performance_measurement_end" command.
Action: Rename the old "perf.out" file, or move it to another directory.
File transfer aborted (410)
Cause: A transfer operation was aborted due to a break received, most likely
a <CTRL>c from the keyboard.
Action: If you typed <CTRL>c, you probably did so because you thought the
transfer was about to fail. Retry the transfer, making sure to use the correct
command options. If you are unsuccessful, make sure that the data
communications parameters are set correctly on the host and on the
HP 64700, then retry the operation.
Guarded memory access break (614)
Cause: This message is displayed if the emulation processor attempts to read
or write memory mapped as guarded.
Action: Troubleshoot your program; or, you may have mapped memory
incorrectly.
Guarded memory break: %s" (628)
Cause: A memory access to a location mapped as guarded memory has
occurred during execution of the user program.
Action: Investigate the cause of the guarded memory access by the user
program.
HP 64700 I/O error; communications timeout
Cause: This is a communication failure.
Action: Check power to the emulator and check that all cables are connected
properly. If you are using LAN and heavy LAN traffic is present, try setting
the environment variable to HP64700TIMEOUT="30" (or larger if needed).
The value is the number of seconds before timeout occurs. Then try running
again.