Getting Started
Step 10: Trace the program
5
To view the captured states, choose Display→Trace.
Or, using the command line, enter:
display trace
Figure 10
The default display mode settings cause source lines and symbols to appear
in the trace list.
Captured states are numbered in the left-hand column of the trace list. Line
0 always contains the state that caused the analyzer to trigger.
Other columns contain address information, data values, opcode or status
information, and time count information.