Error Messages
Read PC failed during break (603)
Cause: System failure or target condition.
Action: Try again.
Record checksum failure (400)
Cause: During a transfer operation, the checksum specified in a file did not
agree with that calculated by the HP 64700.
Action: Retry the transfer operation. If the failure is repeated, make sure
that both your host and the HP 64700 data communications parameters are
configured correctly.
Records expected: %s; records received: %s (401)
Cause: The HP 64700 received a different number of records than it
expected to receive during a transfer operation.
Action: Retry the transfer. If the failure is repeated, make sure that the data
communications parameters are set correctly on the host and on the
HP 64700.
Register access aborted (630)
Cause: Occurs when a <CTRL>c is entered during register display.
Register class cannot be modified: %s (637)
Cause: You tried to modify a register class instead of an individual register.
Action: You can only modify individual registers. Refer to the display
registers command description for a list of register names.
Register not writable: %s (636)
Cause: This error occurs when you attempt to modify a read only register.
Action: If this error occurs, you cannot modify the contents of the register
with the modify register command.