LAN SYSTEM (DIAGNOSTICS)
No.
Data
12
Hazard answer-back setup
13
Automatic locking setup
14
Ans.-back Buzzer
15
Auto locking
16
Initial Keyless Setting
17
Initial button setting
18
Initial Security setting
19
Passive Alarm (Not used)
Door open warning (preven-
20
tion of battery run-out)
(Specification) Security
21
setup
5) After setting, make sure that vehicle equipment is same as the setting changed in the {Current Data Dis-
play & Save}.
CAUTION:
• It is possible to control the original functions of vehicle when settings above are corresponded to
vehicle equipment.
• Do not change the settings except for setting above during operation of equipment setting.
• Be sure not to change Factory initial setting except installation of new body integrated module.
NOTE:
For details concerning operation procedure, refer to the SUBARU SELECT MONITOR OPERATION MAN-
UAL.
Subaru Select Monitor
Initial
setting
Customize setting
value
ON
ON
OFF
ON
ON
OFF
ON
ON
OFF
ON
ON
OFF
Execution
Execution
Execution
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
LAN(diag)-22
Remarks
Workable when hazard answer-back setup is set to "ON".
When lock/unlock is selected by keyless entry system oper-
ated, hazard answer-back buzzer operates.
When lock/unlock is selected by keyless entry system oper-
ated, hazard answer-back does not operate.
Workable when Automatic locking setup is set to "ON".
Automatic locking operates.
Automatic locking does not operate.
Vehicle is controlled in answer-back buzzer equipped
mode.
Vehicle is controlled in answer-back buzzer non-equipped
mode. (Set Ans.-back Buzzer to "OFF" in model without
answer back buzzer.)
Vehicle is controlled in auto locking equipped mode.
Vehicle is controlled in auto locking non-equipped mode.
(Set Auto locking to "OFF" in model without auto locking.)
Settings of keyless entry system are initialized. (No. 2: 30
sec., No. 11: ON, No. 12: ON, No. 13: ON, No. 14: ON)
Settings of each function are initialized. (No. 1: Normal, No.
3: 15 min., No. 4: 15 min., No. 8: ON)
Settings of security system are initialized. (No. 5: OFF, No.
6: OFF, No. 7: ON, No. 10: OFF)
Applicable to North America model (If Passive Alarm is set
to "ON", nothing operates and there is no negative effect.)
If detecting door open for 30 minutes, room light, key illumi-
nation and door warning light are turned off to prevent bat-
tery run-out.
Room light, key illumination and door warning light is not
turned off.
Operate the selected security set. (EK model)
Normally in active condition