Speed - Cisco 300 Series Cli Manual

Stackable managed switches
Hide thumbs Also See for 300 Series:
Table of Contents

Advertisement

29
641
Parameters
console—Enters the terminal line mode.
telnet—Configures the device as a virtual terminal for remote access
(Telnet).
ssh—Configures the device as a virtual terminal for secured remote access
(SSH).
Command Mode
Global Configuration mode
Example
The following example configures the device as a virtual terminal for remote
(Telnet) access.
switchxxxxxx(config)#
switchxxxxxx(config-line)#

29.4 speed

To set the line baud rate, use the speed command in Line Configuration mode.
To restore the default configuration, use the no form of this command.
Syntax
bps
speed
no speed
Parameters
bps—Specifies the baud rate in bits per second (bps). Possible values are 4800,
9600, 19200, 38400, 57600, and 115200.
Default Configuration
The default speed is 115200 bps.
line telnet
OL-32830-01 Command Line Interface Reference Guide