Qos Information Settings; Qos Information; Qos Cosmap - Fujitsu XG0224 User Manual

Hide thumbs Also See for XG0224:
Table of Contents

Advertisement

XG Series User's Guide
5.7

QoS Information Settings

This section explains about QoS information settings.
5.7.1

QoS Information

This section explains about the commands related to QoS information.
5.7.1.1

qos cosmap

Function
Available Model
Syntax
Options
Use Mode
Explanation
Default
Set the correspondence between the COS value and storage queue for a specific packet.
XG0224 / XG0448 / XG0440DC / XG0440DCR
qos cosmap <cos> <queue>
<cos>
• cos value
Set a cos value (user priority value in the Tag Control Information (TCI) field of Tagged
VLAN) of the packet where the specified queue is to be stored, with a decimal value
from 0 to 7.
<queue>
• Queue number
Set the number of a queue to store the packet, which has the cos value specified in
<cos>, with a decimal value.
A larger value has a higher priority.
Range
0 to 7
XG0224 / XG0448 / XG0440DC / XG0440DCR
Configuration mode (admin class)
This product has 8 keys.
Packets are queued in multiple queues of an output port (including a port for the local
device). Which queues are to be selected is determined by the COS value of an output
packet.
Store the packet, which has the cos value specified in <cos>, in the queue specified in
<queue>.
A larger queue number has a higher output priority.
A queue with no cos value is unavailable.
qos cosmap 0 2
qos cosmap 1 0
qos cosmap 2 1
qos cosmap 3 3
qos cosmap 4 4
qos cosmap 5 5
qos cosmap 6 6
qos cosmap 7 7