Fujitsu XG0224 User Manual page 572

Hide thumbs Also See for XG0224:
Table of Contents

Advertisement

XG Series User's Guide
The following example shows the information that is displayed when the
Execution Example
8)
PSU1 type
Type of the power unit (PSU1).
PSU2 type
Type of the power unit (PSU2).
AC
--
9)
power_consumption
Power consumption of the device.
10)
FAN1 state
State of the fan module 1.
FAN2 state
State of the fan module 2.
NORMAL
FAIL
NO_PRESENT : The fan module is not installed.
UNKNOWN
WARNING
11)
inspiration_state
State of environment temperature monitor.
internal_state
State of device inside temperature monitor.
NORMAL
WARNING
ALARM
12)
State of changing thermal state
warning time
recover time
13)
inspiration_temp
Environment temperature.
internal_temp
Device inside temperature.
Execution Example (XG0224)
# show ether media-info
Port media type Vendor PN
---- ---------- ----------------
(1) (2)
(3)
21
SFP(SX)
HFBR-5710L
22
SFP(ZX)
SCP6P94-F7-BMH
23
SFP(LX)
SCP6P44-F7-BMH
24
SFP(FX)
HFBR-57E0P
25
SFP+(LR)
FTLX1471D3BCL
26
SFP+(SR)
TRS2000EN-S002
: The power unit is AC.
: The power unit is not installed or invalid type.
: The fan module works normally.
: The fan module has been abnormal.
: The fan module is invalid direction.
: The fan module has been incorrectly mounted.
: The temperature is normal.
: The device changes to a high temperature state.
: Thermal alarm occurs in the device.
: The time when a device changed in a high temperature state.
: The time when a device returned to a normal state.
"show ether media-info"
572
Chapter 6 Managing the Device
command is entered.
Verifying the Device Operations

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xg0448Xg2600Xg0440dcXg0440dcr

Table of Contents