39.2
Restoring Defaults using Hardware Reset Button
The device's hardware reset pinhole button can be used to reset the device to default
settings.
To restore default settings using the hardware reset pinhole button:
With a paper clip or any other similar pointed object, press and hold down the reset
pinhole button, located on the front panel for at least 12 seconds (but no more than 25
seconds).
39.3
Restoring Defaults using an ini File
You can restore the device to factory default settings by loading an empty ini file to the
device. This is done using the Web interface's Configuration File page (see 'Backing Up
and Loading Configuration File' on page 555). If the ini file does include content (e.g.,
parameters), ensure that they are on lines beginning with comment signs (i.e., semicolons
";") so that the device ignores them.
Note:
User's Manual
The only settings that are not restored to default are the management
(OAMP) IP address and the Web interface's login user name and password.
566
Mediant 800B GW & E-SBC
Document #: LTRT-10274