Ac Regulator Inspection - Honda Motorcycle Service Manual

Honda motorcycles and motor scooters and atvs common service manual
Hide thumbs Also See for Motorcycle:
Table of Contents

Advertisement

BATTERIESICHARGINGILIGHTING SYSTEM
AC REGULATOR INSPECTION
After checking that all connections are correct and secure.
inspect the alternator unit by measuring the resistance
between the terminals. (Refer t o the Model Specific manual
for service data.)
NOTE
The resistance readings will not be accurate if the probes
touch your fingers.
Use one of the following recommended multimeters.
.
Other testers may not allow you to obtain the specified
values. This is due to the characteristic of semicon-
ductors, which have different resistance values depen-
ding on the applied voltage.
SPECIFIC MULTIMETERS
- K S - A H M - 3 2 - 0 0 3
IKOWA Digital type: USA
only)
-07308-0020001
(SANWA Analogue type)
-TH-5H
(KOWA Analogue type)
Select the following range.
SANWA Tester:
k0
KOWA Tester:
x 1 0 0 0
An old, weak multimeter battery could cause inaccurate
readings. Check the battery if the multimeter registers
incorrectly
When using the Kowa rnultimeter, remember that all
readings should be multiplied by 100
If the resistance between the terminals is out o f standard
value, replace the regulator with a new one.
ACREGULATOR
2 2-26
Date of Issue: March, 1995
0
HONDA MOTOR CO..LTD.