Section 5. Zone Programming; About Zone Programming; Zone Programming Procedure - ADEMCO VISTA-20P Installation And Setup Manual

Hide thumbs Also See for VISTA-20P:
Table of Contents

Advertisement

• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •

About Zone Programming

56 Zone Programming is used to program zones, zone types, report codes, enroll 5800 RF Wireless
Transmitter serial numbers, and identify the type of loop input device(s). This mode can also be used
to enter alpha descriptors for programmed zones; however, we recommend entering descriptors in
menu mode
82 (Alpha Descriptor Programming after all zone programming has been completed).
For a faster method of zone programming, you can use the
56 Zone programming. The
previous experience in programming control panels of this type.
NOTE: Alpha display prompts are shown in a double-line box.

56 Zone Programming Procedure

Zone Programming involves:
1. Entering the zone number to be programmed;
2. Making appropriate entries at the prompts;
3. Confirming the serial number of wireless transmitter zones.
Start Zone Programming mode by pressing
prompts are displayed:
PROMPT
SET TO CONFIRM?
0 = NO 1 = YES
Enter Zn Num.
(00 = Quit)
10
Zn ZT P RC
In: L
10 00 1 10
RF: 1
OR
Zn ZT P RC
In: AD
10 00 1 10
AW: 07
OR
Zn ZT P RC
HW: RT
10 00 1 10
EL
1
58 Expert Programming Mode is designed for those who have had
VALID ENTRIES
Set to Confirm
0 = no
1 = yes
Zone Number
VISTA-20P: 01-64
VISTA-15P: 01-06, 09-34, 49-56
Both Controls: 91, 92, 95, 96, 99
00 to quit
[ ∗ ] to continue
Summary Screen
[ ∗ ] to continue
Zone Programming
(
56 and
58 Expert Programming Mode instead of
56 while in Data Programming mode. The following
EXPLANATION
If 1 (Yes) is entered, you will be prompted to confirm each
transmitter after entering the serial and loop numbers (at the "XMIT
TO CONFIRM" prompt later in this procedure). We recommend
that you confirm the programming of every transmitter.
Enter the zone number that you wish to program. Zone 10 has been
entered as an example in the display at left.
Enter a report code for zone 91 to enable addressable device
reporting.
Enter a report code for zone 92 to enable duress reporting.
95, 96, 99 are emergency (panic) key zones.
A summary display appears.
"IN: L" appears for wireless zones and indicates input type and loop.
"IN: AD" appears for hardwire expansion zones (AW) and indicates
the module's address (AD), which is based on the zone number.
"HW: RT" appears for hardwire zones and indicates configuration
(EOL, NO, NC, zone doubling, double-balanced) and response time
selection.
S E C T I O N
58 Menu Modes)
5
5-1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vista-20pcnVista-15pVista-15pcn

Table of Contents

Save PDF