22.Select the
Coverage Hole Recovery
Figure 6-36 Smart RF Recovery screen - Coverage Hole Recovery tab
23.Set the following
Coverage Hole Recovery for 5.0 GHz
Client Threshold
SNR Threshold
Coverage Interval
tab.
Use the spinner to set a client threshold between 1 - 255. This is the
minimum number of clients a radio should have associated for coverage
hole recovery to trigger. The default setting is 1. AP-6532, AP-7131,
AP-7161 and AP-8132 model access points support up to 256 clients per
access point or radio. AP-6511 and AP-6521 model access points support
up to 128 clients per access point or radio.
Use the spinner control to set a signal to noise threshold (between 1 - 75
dB). This is the signal to noise threshold for an associated client as seen
by its associated AP radio. When exceeded, the radio increases its
transmit power to increase coverage for the associated client. The default
value is 20 dB.
Define the interval when coverage hole recovery should be initiated after
a coverage hole is detected. The default is 10 seconds for both the 2.4 and
5.0 GHz radios.